PDT110A and PDT100A compact
neutron monitoring modules designed for high radiation environments connect
directly He-3 detectors. Each instrument contains a precision wide band charge
sensitive pre-amplifier followed by an amplifier, wave shaping and discriminator
circuits. When connected to He-3 detectors, these instruments detect the
presence of charged-sensitive particles. Our focus is to create a compact (1
inch diameter), simple to use, high performance instrument with a variety of
features available.
 |
Each
instrument has an analog monitoring test point allowing direct monitoring
of amplified charged events using an oscilloscope. A twelve turn trim pot
is available to finely tune the amplifier sensitivity to the desired level
so you can obtain a good HV plateau for your application. |
 |
In
addition, when a charged event is detected, a TTL OUT pulse is produced. |
 |
The
TTL OUT pulse width is adjustable from 40nSeconds to 500nSeconds.. |
 |
Each
instrument contains a TTL IN input allowing you to sum outputs from other
modules in a system. This allows quick and easy interconnection from 1 to
over 100 detectors for digital pulse counting measurements. |
 |
Each
instrument contains a threshold control trim pot allowing you to control
the discriminator level for your application. |
 |
The
PDT100 is equivalent in performance to the PDT110A but additionally contains
a high performance high voltage generator that can be adjusted over a
range of 0-2200 volts. |
 |
The
PDT100 contains a HV MON test point that allows you to measure and adjust
the high voltage setting. |
 |
The
PDT110 is compact, housed in 1 inch diameter aluminum with a length of 1.5
inches. |
 |
The
PDT100 is enclosed in 1 inch diameter aluminum with a length of 3 inches. |
PDT110A and PDT100A modules
have been designed for extended temperature and vibration environments. The
products have been tested at temperatures ranging from 0-170 degrees Centigrade
including vibration to 70g from 2Hz to 10kHz.This new generation of neutron
monitoring modules allow new systems to be quickly configured and existing
detector instruments to be easily upgraded. The charge sensitive amplifiers are
designed for Helium-3, boron loaded, fission chamber, alpha-and proton-recoil
neutron detector operation. Multiple modules can be easily interconnected
providing a single digital counting channel that will process pulse rates
exceeding 5 MHz. Engineered in a compact ruggedized aluminum housing that
interfaces directly to gas filled detectors, these modules provide an efficient
clean solution in difficult environments.
Additional Features
Additional features include a light emitting-diode (LED) and two trimpots. The
LED provides visual indication when a neutron event has occurred. Two trimpots
allow control of the amplifier sensitivity ("THRES ADJ ")and "TTL
OUT " pulse width. The trimpots are located just beneath the hole locations
labeled as "THRES ADJ " and "PW ADJ ".Refer to Figure 2 on
the reverse side.
| Specifications |
| TTL
OUT Pulse Width Adjustment Range |
50nSec
to 500nSec |
| Pulse
Pair Resolution |
500nSeconds |
| Power
Supply Options |
+5
Volts or +12 Volts |
| Power
Supply Current Requirements |
@5V
30mA,@12V 20mA |
| Gain
Sensitivity Adjustment Range |
20:1 |
| Threshold
Adjustment Range |
.005pC
to .05pC |
| HV
BIAS Range:PDT100A Only |
0
to 2200 Volts |
| HV
BIAS Noise |
.02Volts
at HV Output |
| HV
BIAS Stability per hour |
.05
Volts at HV Output |
| HV
BIAS Stability per 24 hour |
.1
Volts at HV Output |
| Maximum
TTL IN summing capability |
5,000,000
counts |
Digital Cascade Summing
All PDT110A and PDT100A modules provide an input labeled "TTL IN "
intended for cascade or summed pulse applications. For cascade operation, the
"TTL OUT " of a PDT110A is connected to the "TTL IN " of
another PDT110A.Suppose you have an application requiring three detectors. Three
modules are interfaced directly to the HN connectors of three detectors. The
bias supply and power supply cables are attached to the PDT110A "HV IN
" and "Vcc " connectors, respectively. For cascade operation, the
"TTL OUT " of one PDT110A instrument is cabled to the "TTL IN
" of another PDT110A..In a similar manner, the "TTL OUT " of the
second PDT110A is cabled to the remaining PDT110A "TTL IN " input. The
"TTL OUT " of the final PDT110A is cabled to the monitoring equipment.
PDT110A and PDT100A
Configurations
You can purchase PDT110A and PDT100A modules with a variety of connector
interfaces for He-3 detectors. Modules have the capability to connect directly
to Helium-3 gas filled detectors that us HN, MHV, or SHV type of connectors. If
necessary, you can even cable directly from the PDT110A modules to the detector
using a high voltage cable with the 110A-C.The 110A-C uses a miniature high
voltage connector rated for 5000 volts allowing cable connection to the
detector. PDT can provide the cable with the desired connectors for your
application. Please contact us and we will discuss the cable length, type of
connection on the detector to help simplify your setup. When using the 110A-C it
is important that the cable length is kept as small as possible to minimize both
capacitance and noise. Most PDT modules connect directly to He-3 detectors to
minimize capacitance with the added advantage of providing a more ruggedized
interface.
| 110A
Detector Interface |
100A
Detector Interface |
Description |
| 110A-HN |
100A-HN |
HN
interface to He-3 |
| 110A-SHV |
100A-SHV |
SHV
interface to He-3 |
| 110A-MHV |
100A-MHV |
MHV
interface to He-3 |
| 110A-C |
|
Cable
interface to He-3 |